The product
The solvent-based sealer for the Cemher systems: a two-component aliphatic acrylic polyurethane with high chemical resistance, in gloss, satin or matt. The recoat window is 4 hours to 3 days — miss it and the surface has to be abraded.
Where it is used
- Sealing microcement and lime plaster systems
- Metals and multiple other substrates
- Areas requiring high chemical resistance
Substrates
- Microcement and lime plaster, hardened and below 5% moisture
- Metals
- Multiple mineral substrates
Application data
Coverage, thickness, mix and cure, as declared by the manufacturer. Site conditions in the Gulf sit at the top of most of these ranges — allow for it in the programme.
| Type | Two-component aliphatic acrylic polyurethane varnish |
|---|---|
| Appearance | Gloss, satin or matt |
| Consumption | 8 – 9 m²/L |
| Touch dry at 23 °C | 4 hours |
| Total drying at 23 °C | 24 hours |
| Recoat | 4 hours minimum, 3 days maximum |
| Workability at 20 °C | Approx. 2 hours |
| Operating conditions | 12 – 25 °C, relative humidity below 80% |
| Minimum application temperature | + 10 °C |
| Packaging | Comp A 4 L, in matt, satin or gloss |
| Shelf life | 24 months from manufacture, stored correctly |
Performance data
Every figure below is reproduced from the manufacturer's own technical data sheet, with the test standard it was measured against. The sheet itself is in the download section.
| Property | Result | Standard |
|---|---|---|
| Chemical resistance | High resistance to chemical agents | Cemher data sheet |
| Drying behaviour | Lower temperatures and higher humidity extend drying | Cemher data sheet |
Where not to use it
The limits are as much a part of the specification as the performance. Everything here is stated on the manufacturer's data sheet.
- Solvent-based — specify Aquamax where a water-based sealer is required
- Operating range 12 – 25 °C with relative humidity below 80%
- Minimum application temperature +10 °C
- Do not apply until the finish is below 5% moisture, measured by meter
- Maximum recoat interval 3 days
Sealer: Cemher Maxipur 100% two-component aliphatic acrylic polyurethane in [matt / satin / gloss], applied at 8–9 m²/L in [two] coats to the finish scheduled. Applied only when substrate moisture is below 5% measured by meter, at 12–25 °C and relative humidity below 80%. Recoat interval not less than 4 hours and not more than 3 days.
Square brackets mark the choices that belong to the project. Send us the finishes schedule and we will return the clause completed, with the sample and mock-up programme against it.
Documents
Every document is the manufacturer's own, reproduced in full and unaltered under our cover. Free to download, no form.
-
Maxipur 100 Primers and sealers · Technical data sheet · 11 pp · 0.8 MBDownload (PDF, 0.8 MB)
-
MAXIPUR 100% Primers and sealers · Voc emissions certificate · issued by Pinturas Kilnher, S.L., Valencia, Spain · 2 pp · 0.6 MBDownload (PDF, 0.6 MB)
-
MAXIPUR 100% Primers and sealers · Safety data sheet · 21 pp · 0.9 MBDownload (PDF, 0.9 MB)
-
MAXIPUR 100% Primers and sealers · Safety data sheet · 21 pp · 1 MBDownload (PDF, 1.0 MB)
The rest of the primers and sealers range
Technical support for the design team
We supply the material and we apply it, so the specification and the workmanship sit with one party. Send a finishes schedule, an elevation or a mood board and we will come back with the system, the build-up, the sample programme and a completed clause.