The system
What sits against what, from the substrate outwards. Junctions, movement joints and edge details are project-specific — send us the drawings and we will mark them up.
Interior clay plaster on board or masonry
The standard interior build-up. Refer to the Clayworks Design Details sheet for junction and substrate detail.
Performance data
Taken from the manufacturers' own technical data sheets, with the standard each figure was measured against. Product-level figures are on the product pages below.
| Property | Result | Standard |
|---|---|---|
| Reaction to fire | Euroclass A1 | EN 13501 and EN 15824 |
| Thermal conductivity | 0.84 W/mK (Smooth, Demi-Rustic); 0.97 W/mK (Rustic) | Clayworks data sheets |
| Moisture buffer value | 1.28 (Smooth); 1.4 (Demi-Rustic, Rustic) | Clayworks data sheets |
| Impact | Impact diameter < 15 mm | BS EN 520 |
| Acoustics | NRC 0.10 (Smooth) to 0.25 (Rustic), depending on backing board | BS EN ISO 354 |
| Light reflectance value | 20.0 to 62.7 across the range, by colour and finish | BS 8493:2008 + A1:2010 |
| Embodied carbon | 0.048 – 0.0677 kg CO₂e/kg (A1–A3) | Clayworks EPD, stages A1–A3 |
| Warranty | 10 years manufacturer's warranty, subject to correct detailing, application and maintenance | Clayworks v2.0 data sheets |
| Life expectancy | 60 years interior; 25 years + exterior | Clayworks v2.0 data sheets |
| Colours | 89 standard, plus custom matching | Clayworks v2.0 data sheets |
Products in this family
One page per technical data sheet. Each carries the manufacturer's declared figures, the limits, a specification clause and the full document set.
Where not to use it
Specifying a material into the wrong place is the most expensive mistake on a finishes package. These are the limits we will raise at review whether or not they are asked about.
- Interior walls and ceilings, and fixed furniture. Bathrooms and kitchens are appropriate.
- Not for wet or shower areas, and not for splash zones in direct contact with oils and fats.
- Not suitable for floors, standard doors, or elements subject to frequent movement.
- Not to be applied directly onto timber, plywood, MDF or OSB.
- Exterior grades are a separate specification with a separate build-up and a two-month cure.
- Custom finishes must be installed by an approved applicator.
Clay plaster: Clayworks [Smooth / Demi-Rustic / Rustic] Finish in colour [ref], applied to [2 mm in two coats / 4–5 mm / 6–8 mm] over Clayworks Wall Primer on the substrate scheduled, to the approved sample panel. Reaction to fire Euroclass A1 to EN 13501 and EN 15824. Substrate preparation and junctions to the Clayworks Design Details sheet. Supply and application by Conmarble Natural Finishes as approved applicator. Clayworks Glaze to surfaces scheduled to be wiped clean.
Square brackets mark the choices that belong to the project. Send us the finishes schedule and we will return the clause completed, with the sample and mock-up programme against it.
Document library
Every publishable document for this family, reproduced in full and unaltered under our cover. Free to download, no form.
-
Auro Plaster Primer No 301 Primers and sealers · Technical data sheet · 3 pp · 0.9 MBDownload (PDF, 0.9 MB)
-
CEMHER CLAYWASH Clay plaster · Product guide · 16 pp · 4.7 MBDownload (PDF, 4.7 MB)
-
Cemher Claywash Clay plaster · Technical data sheet · 5 pp · 1 MBDownload (PDF, 1.0 MB)
-
CLAYWORKS Clay plaster · Brochure · 54 pp · 8.1 MBDownload (PDF, 8.1 MB)
-
CLAYWORKS Clay plaster · Brochure · 55 pp · 7.5 MBDownload (PDF, 7.5 MB)
-
CLAYWORKS CLAY PLASTERS Clay plaster · Technical data · 10 pp · 0.8 MBDownload (PDF, 0.8 MB)
-
CLAYWORKS CLAY PLASTERS Clay plaster · Product overview · 6 pp · 1 MBDownload (PDF, 1.0 MB)
-
Exterior Demi-Rustic Finish Clay plaster · Technical data sheet · 5 pp · 1 MBDownload (PDF, 1.0 MB)
-
Exterior Rustic Finish Clay plaster · Technical data sheet · 5 pp · 1.2 MBDownload (PDF, 1.2 MB)
-
Interior Demi Rustic Finish Clay plaster · Technical data sheet · 5 pp · 1.1 MBDownload (PDF, 1.1 MB)
-
Interior Rustic Finish Clay plaster · Technical data sheet · 5 pp · 1 MBDownload (PDF, 1.0 MB)
-
Light Reflectance Values Clay plaster · Technical data sheet · 7 pp · 0.7 MBDownload (PDF, 0.7 MB)
-
Rammed Earth Finishes Rammed earth · Technical data sheet · 7 pp · 1.9 MBDownload (PDF, 1.9 MB)
-
Smooth Finishes Clay plaster · Technical data sheet · 4 pp · 0.7 MBDownload (PDF, 0.7 MB)
-
Tadelakt Clay plaster · Technical data sheet · 6 pp · 1 MBDownload (PDF, 1.0 MB)
-
CEMHER CLAYWASH Clay plaster · Application guidelines · 8 pp · 3.2 MBDownload (PDF, 3.2 MB)
-
CLAYWORKS CLAY PLASTERS Clay plaster · Design details · 19 pp · 2.8 MBDownload (PDF, 2.8 MB)
-
CLAYWORKS CLAY PLASTERS Clay plaster · Application guidelines · 12 pp · 0.7 MBDownload (PDF, 0.7 MB)
-
CLAYWORKS CLAY PLASTERS Clay plaster · Sustainability data · 15 pp · 2 MBDownload (PDF, 2.0 MB)
-
CLAYWORKS CLAY PLASTERS Clay plaster · Voc emissions & content certificates · 5 pp · 0.9 MBDownload (PDF, 0.9 MB)
-
CLAYWORKS CLAY PLASTERS Clay plaster · Voc emissions test reports · 141 pp · 8.3 MBDownload (PDF, 8.3 MB)
-
CLAYWORKS CLAY PLASTERS Clay plaster · Sustainability data · 14 pp · 5 MBDownload (PDF, 5.0 MB)
-
CLAYWORKS CLAY PLASTERS Clay plaster · Healthy buildings data · 13 pp · 1.8 MBDownload (PDF, 1.8 MB)
-
CLAYWORKS DEMI-RUSTIC & RUSTIC Clay plaster · Health product declaration · issued by Health Product Declaration Collaborative (HPDC) — HPD v2.3, UID 945593671680 · 9 pp · 0.6 MBDownload (PDF, 0.6 MB)
-
CLAYWORKS Clay plaster · Quality policy · 4 pp · 1 MBDownload (PDF, 1.0 MB)
Featured projects
Built with this material, by our own artisans. Open the project for the full set of photographs and the story of the installation.
Related systems
Technical support for the design team
We supply the material and we apply it, so the specification and the workmanship sit with one party. Send a finishes schedule, an elevation or a mood board and we will come back with the system, the build-up, the sample programme and a completed clause.